Permabond ET5164M Food-Contact Epoxy Adhesive for Stainless Steel

Need Datasheets? Need Accessories?

• Click Here to visit our Datasheet Server (TDS, SDS, Fact Sheets, Selector Guides, etc)
• Check out Popular Accessories below by scrolling down just a bit on this page.
Shelf Life
Size
SKU: PBND_ET5164M_50ML
Regular price $ 49.99 USD
Currently Out of Stock Call for ETA
Currently Out of Stock Place Order and Call for ETA

SKU

  • Type Epoxy
  • Vendor Permabond
  • SKU PBND_ET5164M_50ML

Permabond ET5164M: Food-Contact Epoxy for Stainless Steel

Permabond ET5164M is the U.S.-available formula offered in place of ET5164. This two-part epoxy is designed primarily for bonding stainless steel in food-contact applications, and also bonds steel and aluminum. Its lightly thixotropic paste consistency, simple 1:1 mix ratio by volume and room-temperature cure make it a practical choice for professional metal assembly and repair.

Permabond describes ET5164M as designed to comply with FDA 21 CFR 175.300 and EU food-contact regulation 10/2011. Use these manufacturer statements when evaluating the adhesive for your particular finished assembly, food-contact conditions and curing process. Confirm application suitability before production.

Why Choose ET5164M?

  • Stainless steel adhesion: developed for stainless steel bonding in food-contact applications.
  • High shear strength: typical stainless steel results of 17-23 N/mm² (2,470-3,340 psi) after a one-hour cure at 60°C.
  • Time for positioning: published gel time of 50-70 minutes for 10 g mixed at 23°C.
  • Flexible curing: full cure in 24 hours at 23°C, or one hour at 60°C.
  • Gap filling: maximum published gap fill of 2 mm (0.08 in.).

Applications

Consider ET5164M for stainless steel assemblies used in food and beverage equipment, metal components in appropriately designed processing machinery, and steel or aluminum fabrication. Its longer gel time can help with careful alignment before clamping. The two cartridge sizes suit different dispensing needs: select 50 mL for smaller jobs or 400 mL for larger assemblies and repeated application.

Select the cartridge size and Shelf Life option that suit your project. Confirm that material condition meets your project requirements, especially for food-contact work. Short shelf life or recently expired material should be evaluated for the intended use; published fresh-material performance should not be assumed for expired stock.

Technical Data

Property ET5164M
Adhesive type Two-part epoxy; lightly thixotropic paste
Part A / Part B composition Epoxy resin / modified amine
Part A / Part B appearance White paste / off-white paste
Viscosity at 25°C (77°F), Part A / Part B 54,000 / 52,000 mPa·s (cP)
Specific gravity, Part A / Part B 1.23 / 1.14
Mix ratio by volume 1:1
Maximum gap fill 2 mm (0.08 in.)
Gel time at 23°C (73°F), 10 g mixed 50-70 minutes
Working strength at 23°C (73°F) 8 hours
Full cure at 23°C (73°F) 24 hours
Working strength at 60°C (140°F) 20 minutes
Full cure at 60°C (140°F) 1 hour
Stainless steel shear strength, ISO 4587* 17-23 N/mm² (2,470-3,340 psi)
Aluminum shear strength, ISO 4587* 12-14 N/mm² (1,740-2,030 psi)
Hardness, ISO 868 75-85 Shore D
Storage temperature 5-25°C (41-77°F)
Manufacturer food-contact statements FDA 175.300 and EU 10/2011

*Typical shear results after one hour at 60°C. Strength varies with surface preparation and bond gap. The provisional TDS provides guideline data, not a specification. Lower temperatures slow curing; larger mixed quantities and higher temperatures shorten usable pot life. Cured strength decreases as service temperature rises, so validate the joint under its actual operating conditions.

Dispensing Accessories

50 mL: use a compatible 1:1 dispenser, such as the Maven DMA50, with the MIXPAC MBQ 05-24L static mixer.

400 mL: pair the appropriate 1:1 configuration of the Maven MV400-36X dispenser with the MIXPAC MFQ 08-24T F-System mixer. Match accessories to the cartridge size, outlet and ratio.

Application and Cure

  1. Prepare clean, dry, grease-free surfaces. Degrease with a suitable solvent, such as acetone or isopropyl alcohol, where compatible. Aluminum, copper and their alloys may benefit from light abrasion to remove oxide.
  2. Insert the cartridge into the dispenser. Remove the cap and dispense until both components flow, then attach the static mixer.
  3. Apply to one surface and join the parts within the usable pot life. Clamp the assembly until handling strength is reached.
  4. Allow the specified full cure before service. Use a suitable controlled heating process when heat-accelerated cure is required.

Storage and Safe Handling

Store at 5-25°C (41-77°F). Part A causes skin and serious eye irritation; Part B causes severe skin burns and eye damage. Both may cause an allergic skin reaction. Wear suitable gloves, protective clothing and eye/face protection, and follow both safety data sheets. Keep Part B locked up. Avoid contact with strong oxidizing materials. For professional or industrial use only; keep out of reach of children.

Technical and Safety Documents